Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

vaillant-logo

Blog

Vaillant Boiler Fault Codes f75: What it is & How to fix it

The Vaillant F75 fault codes typically indicates a problem with the water pressure in your Vaillant boiler. This fault code is commonly found in Vaillant ecoTEC and ecoMAX boilers. When the F75 code appears, it means that the boiler is not detecting adequate water pressure, and it may result in your heating and hot water not working properly. Here's how to fix it:

  1. Check the Water Pressure: The first thing you should do is check the water pressure on your boiler. You can usually find a pressure gauge on the front panel of the boiler. The ideal pressure range is typically between 1 and 2 bar. If the pressure is too low (below 1 bar), you'll need to repressurize the system.
  2. Repressurize the Boiler: To repressurize your Vaillant boiler, follow these steps:

a. Turn off the boiler and wait for it to cool down. b. Locate the filling loop, which is usually a flexible silver or braided pipe that connects the cold water supply to the boiler. c. Open both ends of the filling loop by turning the valves until they are in line with the pipe. d. Slowly open the valve at one end of the filling loop to allow water to flow into the system. Keep an eye on the pressure gauge. e. Once the pressure reaches the recommended range (usually between 1 and 2 bar), close both valves on the filling loop. f. Turn the boiler back on, and the F75 fault code should clear if the pressure was the issue.

  • Check for Leaks: If you find that you need to repressurize the boiler frequently, it's essential to check for any water leaks in the system. Leaks can lead to a drop in pressure, and you'll need to fix the source of the leak to prevent the F75 error from recurring.
  • Call a Professional: If you've checked the water pressure, repressurized the boiler, and still encounter the F75 fault code, it's advisable to contact a qualified heating engineer or a Vaillant service technician. The problem may be related to a faulty pressure sensor, expansion vessel, or another internal component that requires professional diagnosis and repair.

Remember that working on a gas boiler can be dangerous, so if you're not confident in your ability to perform these steps safely, it's always best to seek the assistance of a qualified heating engineer or technician to resolve the F75 fault code and ensure your boiler operates safely and efficiently.